Tikkurila Professional

tikkurila_logo

 
 
 

Tikkurila Industrial

tikkurila_logo

 
 
 

Sayerlack

sayelack_logo_thumb

   

Fire Protection

 envirograf thermoguard-logo

Read More

Aragorn specialise in Fire retardant coating systems for all subatrates and applications.
Sayerlack have 3 Solvent based and 1 waterbased system to maintain Class 0 and 
upgrade to Class 1 classification (BS476)
A,B and C are solvent based systems and D is waterbased.
for Intumescent systems please go to the Fire protection section.
 
 
TA is a code used to encompass the whole fire-retardant coatings system, consisting in two
coats of basecoat (TU 22) and one coat of topcoat (TZ22**).
It is indispensable to comply with the instructions provided in this technical data sheet to ensure
class 1 fire resistance and therefore validity of homologation.
 
Certifications
• UNI 9796 DM 06/03/92 Ministero degli Interni omologazione n° BO1159PVI100001 Cl. 1 di 
reazione al fuoco.
• UNE 23.727-90 Campus de la UAB – Applus – Bellaterra – Barcelona – España expedient 
número 300 8471 Cl. M.1 reacción al fuego por la Arch Coatings España S.L.
• BS 476 – Part 7 – Class 1 – Oak, birch plywood and pine-veneered MDF.
 
 
TB is a code used to encompass the whole fire-retardant coatings system composed of two
coats of basecoat (TU0022/13) and one coat of topcoat (TZ2225/13 or TZ2275/13).
It is indispensable to comply with the instructions provided in this technical data sheet to ensure
class 1 fire resistance and therefore validity of homologation. 
 
Areas of use  
Flat panels (doors), assembled furniture, turned parts. 
Not to be used on veneers glued with thermoplastic resins, assembled parts with cellular or
laminated structure with air cavities (i.e. rattan) or cavities filled with heterogeneous materials. 
 
 
TC is a code used to encompass the whole fire-retardant coatings system composed of two
coats of TU0022/13 basecoat and one coat of TZ2210/00, TZ2225/00 or TZ2275/00 topcoat
mixed with pigmented pastes TP4140/ABC.
It is indispensable to comply with the instructions provided in this technical data sheet to ensure
class 1 fire resistance and therefore validity of homologation.
 
Areas of use 
Flat panels (doors), assembled furniture, turned parts. 
Not to be used on veneers glued with thermoplastic materials, assembled parts with cellular or
laminated structure with air cavities (i.e. rattan) or cavities filled with heterogeneous materials.
 
Certifications
UNI 9796 DM 06/03/92 Ministero degli Interni omologazione n° BO1159PVI100003 Cl. 1 di
resistenza al fuoco.
 
 
TD is a code used to encompass the whole fire-retardant coating system, involving 2 or more
coats.
It is indispensable to comply with the instructions provided in this technical data sheet to ensure
class 1 fire resistance and therefore validity of homologation. 
 
get_quote
aragornpearllogo_thumb
© Copyright 2010 - Aragorn Group - No: 5917979 - Tel: 0844 931 480
Registered Office: 31 Castle Street High Wycombe Bucks HP13 6RU
Website design and SEO by Marketing Collateral Limited